21 March 2016

1. Top Panel

As of release 2010.2, a new feature called Top Panel was added.

The Top Panel is used to display a configurable frame at the top a tabbed pages definition. The content of the top panel is configured through an XML file.

The screenshot below shows a top panel example, and a short description of the areas within the top panel and what they are called.

image

The top panel defines/contains the following areas:

  • Title Form (Shown when the top panel is minimized).

  • Control(s)

    • One control can link to a so-called top-panel form.

    • A control can be used to link other pages using a HREF.

  • A form contains:

    • Section(s) where each section can have a number of Fields

    • A form can be switched between view and edit mode.

  • Tab Menu (name of a menu)

    • Below the top-panel, a tabbed page is shown.

1.1. Top-panel usage

To use the top-panel create a command that has the HREF property set to call the action "loadTopPanel" and pass the name your top-panel configuration through the parameter "panel". See example below:

${ROOT_DIR}/tvc-action/loadTopPanel?panel=tvc:toppanel/Panel.xml

The top panel definition is stored in a directory called "toppanel" among the XML resources (somewhere under /WEB-INF/tvc in your application directory).

If you omit the domain in the resource name, the location of the top panel definition is:

/WEB-INF/tvc/toppanel

If the top panel definition is stored in a domain, for example acme (tvc:toppanel:acme/Panel.xml) then the resource location is:

/WEB-INF/tvc/acme/toppanel

1.1.1. Configuration hierarchy

A typical configuration hierarchy:

image

1.2. Top Panel Configuration

You define your top panel in XML. The root element must be <TopPanel>. Below you find child element definitions.

1.2.1. Child elements TopPanel

Element Name Description Example

Controls

Container element to FormControl and Control

-

TabMenu

Carries the tab menu definition

<TabMenu>tvc:menu/tabs/TabMenu.xml</TabMenu>

Title

Defines the Form to carry the title definition

<Form>tvc:toppanelform/Title.xml</Form>

1.2.2. Child elements FormControl

Element Name Description Example

Form

Defines the Form XML definition

<Form>tvc:toppanelform/Form.xml</Form>

Icon

Points out the icon for the control. Use either Icon or IconClass.

<Icon>${COMMON_DIR}/images/iconSmallDescription.gif</Icon>

IconClass

Defines the CSS class(es) for the font icon for the control. Font awesome is included by default. Use either Icon or IconClass.

<IconClass>fa fa-tags</IconClass>

Label

Carries the tooltip definition for the control

<Label>View/EditDetails</Label>

Access

Defines access rules for the control.

<Access>
    <Role>role_DesignEngineer</Role>
    <Group>group_NameOfGroup</Group>
</Access>

1.2.3. Child elements Control

Element Name Description Example

Height

Defines a specific height for the control

<Height>300</Height>

Href

Defines a href to display in the control

<Href>${COMMON_DIR}/emxLifecycle.jsp</Href>

Icon

Points out the icon for the control. Use either Icon or IconClass.

<Icon>${COMMON_DIR}/iconStatus.gif</Icon>

IconClass

Defines the CSS class(es) for the font icon for the control. Font awesome is included by default. Use either Icon or IconClass.

<IconClass>fa fa-tags</IconClass>

Label

Carries the tooltip definition for the control

<Label>Lifecycle</Label>

Popup

Defines that the control should open in a popup window.

<Popup width="800" height="600"/>

Access

Defines access rules for the section.

<Access>
    <Role>role_DesignEngineer</Role>
    <Group>group_NameOfGroup</Group>
</Access>

1.3. Top Panel Form Configuration

You define your top panel form in XML. The root element must be <Form>. Below you find child element definitions.

1.3.1. Child Elements - Form

Element Name Description Example

Section

Container element for Filed elements. Defines the horizontal field sections in a form

-

1.3.2. Child Elements - Section

Element Name Description Example

Field

Defines a form field

-

Separator

Defines a field that acts as a "separator" in the section.

<Separator/>

Access

Defines access rules for the section.

<Access>
    <Role>role_DesignEngineer</Role>
    <Group>group_NameOfGroup</Group>
</Access>

1.3.3. Child Elements - Field

Element Name Description Example

DataHandler

Point out a class used to retrieve more complex data from matrix. The class must implement the interface com.technia.tvc.core.db.table.evaluator.DataHandler

<DataHandler>
com.technia.acme.datahandler.CalculatedValue
</DataHandler>

Editable

Defines if the field should be editable or not

<Editable />

Expression

Defines an mql expression of the data to retrieve from matrix

<Expression><![CDATA[
$<attribute[attribute_MarketingName].value>
]]></Expression>

FieldCellRenderer

Used to specify alternative rendering for the field. The class must implement the interface com.technia.tvc.core.gui.toppanel.form.render.FieldCellRenderer

<FieldCellRenderer>
com.technia.acme.render.toppanel.BoldItalicValueWithDollarSignAtTheStart
</FieldCellRenderer>

Label

Defines the field label

<Label>Selected Sizes:</Label>

RangeHandler

Defines a range handler class that must implement com.technia.tvc.core.gui.table.RangeHandler

-

Settings

Container element for settings

-

Access

Defines access rules for the section.

<Access>
    <Role>role_DesignEngineer</Role>
    <Group>group_NameOfGroup</Group>
</Access>

AutoCompleteHandler

An autocomplete handler type:

  • type

  • user

  • organization

  • dataset

  • ranges

See Autocomplete chapter for more details.

<AutoCompleteHandler>dataset</AutoCompleteHandler>

AutoCompleteSettings

Settings for autocomplete. Should it be case sensitive, what types to choose from, limits, which dataset to use and other.

The settings vary for each kind of autocomplete handler.

See Autocomplete chapter for more details.

<AutoCompleteSettings>
{
    "handler": {
        "dataset":"tvc:dataset:tvx:enc/ECOs.xml"
    }
}</AutoCompleteSettings>

1.3.4. Child Elements – Settings

Element Name Description Example

Columns

Used with InputType textarea to define columns

<Columns>25</Columns>

InputType

Specifies the type of input

<InputType>textbox</InputType>

InputWidth

Defines the width of the input

<InputWidth>120</InputWidth>

Required

Defines if an editable field should be required or not

<Required>true</Required>

Rows

Used with InputType textarea to define rows

<Rows>2</Rows>

Setting

Define custom settings

<Setting name="Text Length">200</Setting>

SortRangeValues

Defines if to sort range values

<SortRangeValues>true</SortRangeValues>

SearchConfig

Connect a search to a field

<SearchConfig>tvc:searchconfig/s.xml</SearchConfig>

RegisteredSuite

Defines the registered suite. This can be used for localization of labels, where the value of the key is stored in a particular suite string resource file.

<RegisteredSuite>Framework</RegisteredSuite>

Separator

Only valid on a field in a Top panel title. Defines text to be put at the right hand side of a field, used for separating multiple fields. If you specify an empty Separator element then one space will be used.

Values starting and ending with a single quote or double quote will be un-quoted, in order to be able to specify space characters.

<Separator>:</Separator>

<Separator>" , "</Separator>

MaxLength

Specifies the max length of an editable input field.

<MaxLength>20</MaxLength>

MaxRows

Specifies the max number of rows to display of the text.

<MaxRows>3</MaxRows>

ValueIfEmpty

Specifies the value to be used if the actual value is an empty string.

By default, the " " replacement is used.

<ValueIfEmpty>-<ValueIfEmpty>

BadChars

Specifies characters that are treated as "bad" and if the value contains any such character, the user will not be able to modify the value.

<BadChars>*?[]${}\\\"<>|%</BadChars>

ValidationJavaScript

Can be used to declare custom validation JavaScript code that is inserted on the page that displays this form.

<ValidationJavaScript>
validateRange(field, value);
</ValidationJavaScript>

LinkedWith

Can be used if other fields are updated in the background. On a Refresh these fields will be updated as well.

Format: COLUMN:FIELD

Separate multiple fields using a comma.

<LinkedWith>3:3,3:5</LinkedWith>

UseTransactionOnEdit

Can be used to get an update-transaction surrounding the modification of the field.

Default is FALSE.

<UseTransactionOnEdit>true</UseTransactionOnEdit>

1.3.5. Auto Completion

The fields can take advantage of auto-completion. If you have a field that applies to "type" and is editable, the way to configure such field to take advantage of autocomplete is slightly different. See example below:

<Field>
    <Label>Type:</Label>
    <Expression><![CDATA[$<type>]]></Expression>
    <Editable />
    <AutoCompleteHandler>type</AutoCompleteHandler>
    <AutoCompleteSettings>{
        'handler' : {
            'rootTypes' : ['type_HardwarePart', 'type_SoftwarePart']
        }
    }</AutoCompleteSettings>
</Field>

E.g. you use the setting "Type" to specify the "root" type for the object.

If you want to enable autocompletion for users, then you can enable that through the following configuration:

<Field>
    <Label>Owner:</Label>
    <Editable />
    <Expression><![CDATA[$<owner>]]></Expression>
    <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.UserNameHandler</DataHandler>
    <AutoCompleteHandler>user</AutoCompletHandler>
</Field>
Autocomplete Settings

Settings are configured in JSON format in the AutoCompleteSettings element.

Example setting limit to 50, case sensitive, disable localization and only matching values starting with the searched value:

<AutoCompleteSettings>{
    'handler' : {
        'limit' : 50,
        'caseSensitive' : false,
        'localize' : false,
        'contains' : false
    }
}</AutoCompleteSettings>

See the Autocomplete chapter for more details.

1.3.6. Access Control

Both on control, section level as well as per field level, one can restrict access to the control/section/field.

The access restriction can be defined based on following:

  • Role Assignment

  • Group Assignment

  • Person (A named user)

  • Access Mask (Access mask for the current object)

  • Access Program (A JPO that evaluates the access rights)

The example below illustrates how you can construct the access restriction:

<Field> <!-- Or Section -->
    <Access>
        <Role>role_FirstRole</Role>
        <Role>role_SecondRole</Role>
        <Group>group_SomeGroup</Group>
        <Mask>modify,checkout</Mask>
    </Access>
</Field>

Or use an access program:

<Field> <!-- Or Section -->
    <Access>
        <Program name="MyJPO" method="checkAccess"/>
    </Access>
</Field>

1.3.7. Built-in datahandlers

RelatedObjectHandler

This datahandler can be used for modifying related objects, e.g. connecting and disconnecting them.

<Field>
    <Label>Design Organization:</Label>
    <Editable />
    <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.RelatedObjectHandler</DataHandler>
    <FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.RelatedObjectRenderer</FieldCellRenderer>
    <AutoCompleteHandler>organization</AutoCompleteHandler>
    <Settings>
        <Setting name="Relationship">relationship_DesignResponsibility</Setting>
        <Setting name="Direction">to</Setting>
        <Setting name="Display Property">name</Setting>
        <Setting name="OpenInPopup">true</Setting>
        <Setting name="Show Type Icon">true</Setting>
        <Setting name="Show Link">true</Setting>
    </Settings>
</Field>
Setting Description Example

Relationship

The symbolic name of the relationship to use.

relationship_DesignResponsibility

Direction

The direction of the connection

  • from

  • to

Display Property

What to select and display from the connected object(s)

Name

OpenInPopup

Optional parameter to determine the link target.

true

The related object is opened in a new popup window. (Default)

false

The link opens in the same parent window.

Show Link

This setting defines whether to show a link or not on a current business object.

true

The link is displayed.

false

No link is displayed (Default).

Show Type Icon

This setting defines whether to show the current business object type icon or not.

true

The type icon is displayed.

false

No type icon is displayed (Default).

UserNameHandler

This datahandler is used for handling user names. Auto-completion can be configured as well.

<Field>
    <Label>Owner:</Label>
    <Editable />
    <Expression><![CDATA[$<owner>]]></Expression>
    <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.UserNameHandler</DataHandler>
    <AutoCompleteHandler>user</AutoCompleteHandler>
</Field>

Examples

1.3.8. Top-panel configuration example

<TopPanel>
    <Title>
        <Form>tvc:toppanelform/Title.xml</Form>
    </Title>
    <Controls>
        <FormControl>
            <Label>View/Edit Details</Label>
            <Icon>${COMMON_DIR}/images/iconSmallDescription.gif</Icon>
            <Form>tvc:toppanelform/Form.xml</Form>
        </FormControl>
        <Control>
            <Label>Lifecycle</Label>
            <Icon>${COMMON_DIR}/images/iconStatus.gif</Icon>
            <Href>${COMMON_DIR}/emxLifecycle.jsp</Href>
        </Control>
    </Controls>
    <TabMenu>tvc:menu/tabs/TabMenu.xml</TabMenu>
</TopPanel>

1.3.9. Top-panel title form configuration example

<Form>
    <Section>
        <Field>
            <Expression><![CDATA[$<type>]]></Expression>
        </Field>
        <Field>
            <Expression><![CDATA[$<attribute[attribute_Title]>]]></Expression>
            <Settings>
                <Separator>: </Separator>
            </Settings>
        </Field>
    </Section>
</Form>

1.3.10. Top-panel form configuration example

<Form>
    <Section>
        <Field>
            <Label>Style #:</Label>
            <Expression><![CDATA[$<attribute[attribute_StyleNumber].value>
            ]]></Expression>
            <Editable />
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
        <Field>
            <Label>Selected Sizes:</Label>
            <Expression>dummy</Expression>
            <RegisteredSuite>ApparelAccelerator</RegisteredSuite>
            <DataHandler>com.technia.acme.SelectedSizesDataHandler</DataHandler>
        </Field>
        <Field>
            <Label></Label>
            <RegisteredSuite>ApparelAccelerator</RegisteredSuite>
        </Field>
        <Field>
            <Label>Comments:</Label>
            <Expression><![CDATA[$<attribute[attribute_Comment]>]]></Expression>
            <Editable />
            <Settings>
                <InputType>textarea</InputType>
                <Columns>25</Columns>
                <Rows>2</Rows>
                <Setting name="Text Length">200</Setting>
            </Settings>
        </Field>
    </Section>
    <Section>
        <Field>
            <Label>Marketing Name:</Label>
            <Expression><![CDATA[$<attribute[attribute_MarketingName].value>]]></Expression>
            <Editable />
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
    </Section>
    <Section>
        <Field>
            <Label>Season:</Label>
            <Expression><![CDATA[$<to[relationship_ProductMeasurement].from.revision>]]></Expression>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
        <Field>
            <Label>M-Chart Revision:</Label>
            <Expression><![CDATA[$<revision>]]></Expression>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
    </Section>
    <Section>
        <Field>
            <Label>Supplier:</Label>
            <Expression><![CDATA[$<to[relationship_ProductMeasurement].from.to[relationship_ManufacturingResponsibility].from.name>]]></Expression>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
        <Field>
            <Label>Copied From:</Label>
            <Expression>dummy</Expression>
            <DataHandler>com.technia.acme.datahandler.CopiedFromDataHandler</DataHandler>
            <FieldCellRenderer>com.technia.acme.render.toppanel.CopiedFromRenderer</FieldCellRenderer>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
    </Section>
    <Section>
        <Field>
            <Label>State:</Label>
            <Expression><![CDATA[$<current>]]></Expression>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
        <Field>
            <Label>Template Revision:</Label>
            <Expression><![CDATA[$<from.revision>]]></Expression>
            <Settings>
                <InputType>textbox</InputType>
                <InputWidth>120</InputWidth>
                <Required>true</Required>
            </Settings>
        </Field>
    </Section>
</Form>

2. Category Top Panel

As of release 2016.3, a new feature called Category Top Panel was added. Category Top Panel utilizes TVC top panel to show category tree menu. When enabled OOTB tree or category menu is replaced with TVC default category top panel and category menu is rendered using TVC tabs. This provides all the capabilities of TVC tabs like rearranging and hiding tabs. Category Top Panel is flexible and allows configuration / extension to default form. It is also possible to show a different category top panel for the specific type. These configurations are explained in below sections.

The screenshot below shows a default category top panel and a short description of the section within the top panel form.

image
Figure 1. Default Category Toppanel Form
  1. Maximize and minimize toggle.

  2. Form Control

  3. Image drop zone

  4. Name of context object

  5. Type of context object, with the link to higher revision if it exists.

  6. Direct link to pending issues for this context object, shows a table if there are more than one object or else issue object is opened.

  7. Direct link to in-process routes for this context object, shows a table if there are more than one object or else route object is opened.

  8. Description

  9. Previous, current and next state of an object, with links to promote and demote object.

  10. Last modified date with the history of the context object.

  11. Owner of the context object.

  12. Reference document drop zone. On file drop, a new document object is created and connected to a context object.

  13. Direct link to reference document tab when there are more than 2 reference documents connected.

  14. Reference Document with a link to download file. The zip file is generated when there is more than one file checked in.

  15. Enovia actions command to show home page, back, forward and refresh the page.

Category Top Panel App Menu closes only on click of App Menu button. The vertical menus does not support tab cache behavior.
image
Figure 2. Default Category Toppanel

2.1. Usage

Category Top Panel can be enabled for all objects by adding a filter in web.xml as shown below.

<filter>
    <filter-name>TVCCategoryFilter</filter-name>
    <filter-class>com.technia.tvc.core.gui.category.filter.TVCCategoryFilter</filter-class>
    <init-param>
        <param-name>tvc.category.namespace</param-name>
        <param-value>acme:common</param-value>
    </init-param>
    <init-param>
        <param-name>tvc.category.defaultPanel</param-name>
        <param-value>tvc:toppanel:acme:common/DefaultPanel.xml</param-value>
    </init-param>
    <init-param>
        <param-name>tvc.category.showTVCCategory</param-name>
        <param-value>true</param-value>
    </init-param>
 </filter>
 <filter-mapping>
    <filter-name>TVCCategoryFilter</filter-name>
    <url-pattern>/common/emxTree.jsp</url-pattern>
 </filter-mapping>

The table below describes the supported init parameters:

Filter Init Param Description

tvc.category.namespace

This filter param defines the namespace to use for looking up category top panel configured for specific types.

tvc.category.defaultPanel

Default top panel for all types.

tvc.category.showTVCCategory

This parameter can have the value true or false. If set to true, default TVC category top panel is enabled for all types. If set to false, only types which have category menu explicitly defined will have TVC category enabled as per category menu.

2.2. Default Category Top Panel

A default category top panel tvc:toppanel:core:common/DefaultPanel.xml with built-in form fields and sections is available and pre-configured. It is possible to extend this and configure what should be shown in default category top panel form. The filter param tvc.category.defaultPanel can be used to point to default panel.

2.2.1. Default Panel

<TopPanel>
    <Title>
        <Form>tvc:toppanelform:core:common/DefaultTitle.xml</Form>
    </Title>
    <Controls>
         <Control>
            <Label>View/Edit Details</Label>
            <IconClass>ti-c ti-details-c</IconClass>
            <Href>${TVC_ACTION}/showTopPanelForm?form=tvc:toppanelform:core:common/DefaultForm.xml&amp;compactMode=true</Href>
            <Height>80</Height>
        </Control>
    </Controls>
</TopPanel>
Configuration Description

Title

This is similar to title in standard top panel, but title is not displayed when top Panel is rendered in compact mode. This also support java fields similar to top panel form when form is rendered in compact mode.

Title in Category Top Panel does not support editing of data.

compactMode

Used to rendered top panel form in compact mode. By default it is false. When compactMode is false, standard top panel form is rendered.

Height

Height can be specified if form should be rendered in certain size.

2.2.2. Default Form

<Form>
	<Section>
		<Field>
			<DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultImageHandler</DataHandler>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultImageRenderer</FieldCellRenderer>
		</Field>
	</Section>
	<Section>
		<Field>
			<DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.TypeRevisionHandler</DataHandler>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.TypeRevisionRenderer</FieldCellRenderer>
		</Field>
	</Section>
	<Section>
		<Field>
			<Expression>description</Expression>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.TopPanelDescriptionRenderer</FieldCellRenderer>
		</Field>
	</Section>
	<Section>
		<Field>
			<DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultStateHandler</DataHandler>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultStateRenderer</FieldCellRenderer>
		</Field>
	</Section>
	<Section>
		<Field>
			<DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.TopPanelReferenceDocumentHandler</DataHandler>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.TopPanelReferenceDocumentRenderer</FieldCellRenderer>
		</Field>
	</Section>
</Form>

Default form has five sections each having one built-in field, it provides functionality and behaviour similar to Enovia OOTB top panel. Built-in handlers are explained in below sections.

2.2.3. Default Title

<Form>
	<Section>
		<Field>
			<Expression>name</Expression>
		</Field>
	</Section>
	<Section>
		<Field>
			<DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultTitleStateHandler</DataHandler>
			<FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultTitleStateRenderer</FieldCellRenderer>
		</Field>
	</Section>
</Form>
Editable element is not supported in the title form field.

2.2.4. Built in Handlers

Type Revision Handler

This handler is used for showing following details of objects -

  1. Name

  2. Revision

  3. Link to higher revision if exists

  4. Pending issues to the context object.

  5. Pending changes to the context object.

  6. In process routes on the context object.

<Field>
  <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.TypeRevisionHandler</DataHandler>
  <Settings>
    <Setting name="showPendingIssue">true</Setting>
    <Setting name="showPendingChanges">true</Setting>
    <Setting name="showInProcessRoutes">true</Setting>
  </Settings>
  <FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.TypeRevisionRenderer</FieldCellRenderer>
</Field>
Setting Description Example

showPendingIssue

whether pending issues should be shown.

true

showPendingChanges

whether pending changes should be shown.

true

showInProcessRoutes

whether in process routes on objects should be shown.

true

Default Image Handler

This handler is used to render and update the image of an object. Drag and drop are used to uploaded image. When first image is uploaded, it is by default set as primary image. Once image is set as primary, subsequent images are just uploaded. Image editor can be opened by clicking on the image and the new image can be set as primary.

<Field>
  <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultImageHandler</DataHandler>
  <FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.DefaultImageRenderer</FieldCellRenderer>
</Field>
Setting Description Example

ExlcudeFileTypes

The symbolic name of the types for which should be excluded from image drop zone rendering.

type_Project,type_ProjectSpace,type_BusinessSkill,type_ProjectTemplate,type_ProjectConcept

Reference Document Handler

This handler is used to show and upload reference documents. Drag and drop can be used to create a new document. Name of the file uploaded is set as a title of the document object. First two documents are shown in the field and a link to reference document tab is also shown if there more than two reference documents.

<Field>
  <DataHandler>com.technia.tvc.core.gui.toppanel.form.builtin.TopPanelReferenceDocumentHandler</DataHandler>
  <Settings>
    <Setting name="ExlcudeFileKindof">type_Route,type_RouteTemplate,type_Project</Setting>
    <Setting name="ExlcudeFileTypes">type_Project,type_ProjectSpace,type_BusinessSkill,type_ProjectTemplate,type_ProjectConcept</Setting>
  </Settings>
  <Setting name="ShowOnlyIcon">true</Setting>
  <Setting name="ShowOnlyTitle">true</Setting>
  <FieldCellRenderer>com.technia.tvc.core.gui.toppanel.form.builtin.TopPanelReferenceDocumentRenderer</FieldCellRenderer>
</Field>
Preventing Bad Characters in file names

Files that contain bad characters in its name can be prevented from being uploaded, by defining the set of bad characters using the following setting:

In tvc.properties:

tvc.core.toppanel.badFileNameChars = '#$@&%

Or in TVC init-parameter:

<init-param>
    <param-name>tvc.core.toppanel.badFileNameChars</param-name>
    <param-value>'#$@&%</param-value>
</init-param>
Setting Description Example

ExlcudeFileKindof

The symbolic name of the type kindof for which upload file should not be shown.

type_Route,type_RouteTemplate,type_Project

ExlcudeFileTypes

The symbolic name of the types for which upload file should not be shown.

type_Project,type_ProjectSpace,type_BusinessSkill,type_ProjectTemplate,type_ProjectConcept

ShowOnlyIcon

Only reference document icon will be shown if ShowOnlyIcon is set to true. Default value is false. When both ShowOnlyIcon and ShowOnlyTitle are set to false, Document icon, title and modified date is shown. This is also default behavior.

true

ShowOnlyTitle

Reference document icon and title will be shown if ShowOnlyTitle is set to true. Default value is false.

true

RelationshipName

Symbolic name of the relationship through which reference document will be connected with context object.

relationship_ReferenceDocument

Document

Symbolic name of the document type which should be created.

type_Document

Vault

Symbolic name of the vault in which document should be created.

vault_eServiceProduction

Format

Symbolic name of the file format to be used for checkin of file.

format_generic

Policy

Symbolic name of the policy to be used for reference document creation.

policy_Document

ReferenceDocumentCommand

Name of reference document command in category tree menu. It is possible to give different command names for category tree of different type. Default will be used if specific type is not given.

type_Part:ENCSpecAndReferenceDoc, type_Document:APPDocumentFiles, default:ReferenceDocumentsTreeCategory

2.2.5. Default Category

TVC Category Top Panel also supports Enovia Default Category setting. This can be enabled using the following TVC init parameter.

<init-param>
    <param-name>tvc.core.categoryMenu.showDefaultCategory</param-name>
    <param-value>true</param-value>
</init-param>

Default value is False.

2.3. Configurations

2.3.1. Type Specific Category Top Panel

It is possible to define a separate category top panel for any specific type. This can be configured by using category definition defined in namespace as specified in web.xml filter

<filter>
    <filter-name>TVCCategoryFilter</filter-name>
    <filter-class>com.technia.tvc.core.gui.category.filter.TVCCategoryFilter</filter-class> <init-param>
    <param-name>tvc.category.namespace</param-name>
    <param-value>acme:common</param-value>
</init-param>

Category definition follow Enovia type hierarchy and if a category definition exists for type, it is used to load category top panel. If no category definition is found for a type, default category top panel is used.

Sample category top panel configuration

<Category>
    <Action>loadCategoryTopPanel</Action>
    <Param name="panel" value="tvc:toppanel:acme:common/PartPanel.xml" />
</Category>

Action should be loadCategoryTopPanel.

2.3.2. Top Panel Form

It is possible to configure standard top panel form in the default category top panel. This allows to utilize all the capabilities of standard top panel form and still load vertical tab menus. compactMode must be set to false to load standard top panel form. For details on standard top panel form see Top Panel Form Configuration.

Sample Configuration

<TopPanel>
    <Title>
        <Form>tvc:toppanelform:acme:common/Title.xml</Form>
    </Title>
    <Controls>
         <Control>
            <Label>View/Edit Details</Label>
            <IconClass>ti-c ti-details-c</IconClass>
            <Href>${TVC_ACTION}/showTopPanelForm?form=tvc:toppanelform:acme:common/Form.xml&amp;compactMode=false</Href>
            <Height>200</Height>
        </Control>
    </Controls>
</TopPanel>
image
Figure 3. Toppanel Form

2.3.3. Alternate Category Menu

Enovia allows defining alternate category menus for a type based on registered suite in suite/central property file as shown below.

eServiceSuiteProgramCentral.emxTreeAlternateMenuName.type_Project=PMCtype_Project
eServiceSuiteProgramCentral.emxTreeAlternateMenuName.type_ProjectVault=PMCtype_ProjectVault

This feature is by default disabled and can be enabled via init param tvc.core.categoryMenu.enableAlternateCategoryMenu

<init-param>
    <param-name>tvc.core.categoryMenu.enableAlternateCategoryMenu</param-name>
    <param-value>true</param-value>
</init-param>

If present, the category top panel will first try to load the alternate category menu defined for the registered suite and type in suite/central property file. It further navigates the type hierarchy to find the alternate category menu defined for any of parent types. If an alternate category menu is not found, the standard category menu for type will be loaded.